DAC curve example: formula, dB and %DAC worked out
A DAC curve example comes down to three formulas. Join the reference echoes with straight lines to get the curve height at any position, bring the echo back to the reference gain with A' = A × 10^(−ΔG ÷ 20), then compare: dB re DAC = 20 × log10(A' ÷ DAC) and %DAC = 100 × A' ÷ DAC. This article builds a curve from three made-up reference points, plots it, rates two echoes (one read after a gain change) and checks both in the DAC curve calculator. Every number is invented for practice and is not taken from any exam or procedure.
What the curve shows
DAC stands for distance amplitude correction. Evident's flaw detection tutorial describes the curve as a plot of echo heights from reflectors of one size at different distances from the probe. In the far field, farther reflectors give lower echoes because of attenuation and beam spread, so the curve slopes down. An echo from a reflector the same size as the reference ones sits on the curve at any depth, and a bigger or smaller one sits above or below it. The DAC curve guide covers the definition and the figure. This post is the arithmetic.
The DAC curve formulas
- Curve height between two points: DAC(s) = A1 + (s − s1) ÷ (s2 − s1) × (A2 − A1), where s is the echo's position and (s1, A1) and (s2, A2) are the reference points on either side of it.
- Back to the reference gain: A' = A × 10^(−ΔG ÷ 20), where A is the echo height as read and ΔG is how many dB above the reference gain you read it at. Use a negative ΔG if you took gain off.
- dB re DAC: 20 × log10(A' ÷ DAC(s)). Positive means above the curve, negative means below. This is the decibel definition in Evident's glossary, which allows screen percentages as the two amplitudes.
- Percent of DAC: %DAC = 100 × A' ÷ DAC(s).
- Extra lines below the curve: DAC × 10^(−6 ÷ 20) is about 50.1% of the curve and DAC × 10^(−14 ÷ 20) is about 20.0%. Evident's tutorial shows a −6 dB and a −14 dB curve as an example. Your procedure says which lines, if any, you use.
Step 1: the reference points
Three reference reflectors of the same size at three depths, peaked one at a time with the probe and instrument settings fixed. Every height is read at the reference gain.
| Depth | Echo height (% FSH) | −6 dB line (% FSH) | −14 dB line (% FSH) |
|---|---|---|---|
| 15 mm | 80 | 40.09 | 15.96 |
| 35 mm | 52 | 26.06 | 10.38 |
| 55 mm | 34 | 17.04 | 6.78 |
The two right-hand columns are the first column times 0.5012 and 0.1995.
Try one question
Question 1 of the free 10-question check on UT L2. No signup. About 13 minutes. Most checks include 2 calculation questions, with a calculator on the page. Then ask Echo, the AI study assistant, why the answer is right and the others are wrong.
Discontinuity Detection
A planar reflector gives its highest echo amplitude when the beam strikes it
Press A-D or 1-4 to choose an answer while this question is on screen.
Choose an answer to begin
Step 2: plot the curve
Draw depth along the bottom from 0 to 60 mm and % FSH up the side from 0 to 100. Mark the three points and join neighbors with straight lines. Stop at 15 mm and at 55 mm: the curve exists only between the first and last reference point. Repeat for the two lower lines if your procedure uses them.
Two heights you will need, read off the straight lines:
- At 25 mm, halfway between 15 and 35 mm: DAC = 80 + (25 − 15) ÷ (35 − 15) × (52 − 80) = 80 − 14 = 66% FSH.
- At 45 mm, halfway between 35 and 55 mm: DAC = 52 + (45 − 35) ÷ (55 − 35) × (34 − 52) = 52 − 9 = 43% FSH.
Step 3: rate echo 1 at the reference gain
An indication peaks at 25 mm depth at 40% FSH. The gain was not changed, so A' = 40% FSH.
- DAC at 25 mm = 66% FSH (Step 2).
- dB re DAC = 20 × log10(40 ÷ 66) = 20 × log10(0.6061) = −4.35 dB.
- %DAC = 100 × 40 ÷ 66 = 60.6% DAC.
Sanity check: the −6 dB line at 25 mm is 66 × 0.5012 = 33.08% FSH. The echo at 40% sits between that line and the curve, which matches a result between −6 dB and 0 dB.
Step 4: rate echo 2 after a gain change
An indication at 45 mm is hard to see, so you add 6 dB of gain to peak it. On screen it reads 90% FSH.
- Back to the reference gain: A' = 90 × 10^(−6 ÷ 20) = 90 × 0.5012 = 45.11% FSH.
- DAC at 45 mm = 43% FSH (Step 2).
- dB re DAC = 20 × log10(45.11 ÷ 43) = +0.42 dB.
- %DAC = 100 × 45.11 ÷ 43 = 104.9% DAC.
The echo is just above the curve. A taller-looking echo on the screen is not a bigger reflector until the gain is taken back out.
Step 5: check both in the calculator
Open the DAC curve calculator, leave the unit on mm and press "Remove the last point" once, so three point rows are left. Enter the reference points 15 and 80, 35 and 52, 55 and 34. Then:
- Echo 1: position 25, height 40, gain 0. The calculator shows −4.35 dB, 60.6% of DAC and a DAC of 66% FSH at that position.
- Echo 2: position 45, height 90, gain 6. The calculator shows +0.42 dB, 104.9% of DAC, a DAC of 43% FSH and 45.11% FSH at the reference gain.
If your hand answer differs, compare the working line by line. The calculator prints the straight-line step and the gain step it used. Work the problem by hand first: the calculator checks your method, it does not build it.
Common mistakes
- Comparing echoes at different gains. Leave out the gain step for echo 2 and you get 90 ÷ 43 = 209.3% DAC, or +6.42 dB, when the echo is really +0.42 dB. Every 6 dB of extra gain roughly doubles the screen height, so the error is never small.
- Wrong sign on the gain change. Gain you added comes off: the exponent is −ΔG. Enter −6 instead of +6 for echo 2 and you get 417.6% DAC, or +12.42 dB.
- Extrapolating past the last point. An echo at 65 mm is beyond the 55 mm point. Extending the last segment would give 25% FSH, but no reference echo backs that number up. The calculator gives no rating there and asks for a reference point at or beyond 65 mm. Do the same on paper.
- Reading the curve at the wrong position. Using the nearest point's 52% for echo 2 instead of 43% at 45 mm gives 86.7% DAC and −1.24 dB, below the curve instead of above it.
- Mixing sound path and depth. Use one measure for every point and every echo. On an angle beam setup the two differ, as the skip distance worked examples show.
- Reading a clipped echo. Above 100% FSH the screen cannot show the true height. Take gain off until the peak is on screen, then correct for the change as in Step 4.
- Reusing a curve after a change. The curve belongs to one probe, one set of instrument settings and one material. Change any of them and the curve has to be rebuilt or verified under your procedure.
What these numbers do not decide
A dB or %DAC figure is a measurement, not a verdict. Your written procedure and the governing code or standard set the reference reflector, how the curve is built, the scanning level and any recording or acceptance level. This article gives none of those values, and a qualified person makes the call on a real part. For the decibel steps alone, see decibels in ultrasonic testing: the 6 dB and 20 dB rules and the decibel calculator. The UT formulas guide puts the decibel formula next to the rest of the UT math.
See where you stand
Take the free 10-question check for UT Level II. It needs no signup, explains every answer and shows which topics to drill first, decibels and amplitude included.
FAQ
What is the formula for a DAC curve?
Between two reference points (s1, A1) and (s2, A2), the curve height at position s is A1 + (s − s1) ÷ (s2 − s1) × (A2 − A1). An echo is rated against it with dB re DAC = 20 × log10(A' ÷ DAC) and %DAC = 100 × A' ÷ DAC, where A' is the echo height at the reference gain.
How do I rate an echo I read at a different gain?
Bring it back to the reference gain first: A' = A × 10^(−ΔG ÷ 20), with ΔG positive for gain you added. In the example above, 90% FSH read 6 dB hot is 45.11% FSH at the reference gain, which rates +0.42 dB against a 43% curve.
What does −6 dB on a DAC curve mean?
It is half the curve height, so an echo at −6 dB re DAC is about 50% DAC. Evident's tutorial shows a −6 dB and a −14 dB line under a main curve as an example. Which lines apply, if any, is up to your procedure.
Can I extend a DAC curve past the last reference point?
Not with any confidence. Past the last point there is no reference echo to say how the amplitude keeps falling. Add a reference reflector at or beyond the depth you need and rebuild the curve.
Sources
Original arithmetic and examples, written for this article. Checked 21 Nov 2026.
- Ultrasonic Flaw Detection Tutorial (PDF, 2021), Olympus, hosted by Evident: section 8.1, DAC and TVG (p. 56), and the Decibel (dB) glossary entry (p. 72). Checked 21 Nov 2026.
- DAC curve calculator, Angle Beam: every result above was checked in it. Checked 21 Nov 2026.
Angle Beam editorial team
Related guides
Free tools for this topic
Keep reading
Your next step
Ready to see where you stand on UT L2?
Free, untimed and scored by domain. No signup. About 13 minutes. Most checks include 2 calculation questions, with a calculator on the page.
Free 10-question checkNDT UT Level II General course. Lessons, timed practice exams and a plan around your exam date.
Get NDT UT Level II General course · $149More free practice
- Read a free lesson
- Take the free 25-question practice test
- Question of the day
- Free flashcards
- Print the study checklist (free PDF)
- Print a class quiz (free PDF)
- Print the flashcards as cut-out cards (free PDF)
The free check and the course are on the UT L2 page.