How to use the water path calculator
- Pick a mode: the minimum water path for a part thickness, or the water path for a focused probe.
- Pick the length unit (mm or in) and the material. The material list fills in the longitudinal velocity; type your own if you measured it. Water starts at 1,480 m/s, the 20 °C value.
- For the minimum, enter the part thickness T. For a focused probe, enter the focal length in water F and the depth in the part you want to focus at. Add T as well to check the focus water path against the minimum.
The two formulas
- Minimum water path: WP = T × Vw ÷ Vm. In an immersion setup the first echo after the initial pulse is the front-surface echo, which Evident calls the interface echo and uses as the zero for depth. It repeats once every water round trip, 2 × WP ÷ Vw. The first back-wall echo follows the first interface echo by the part round trip, 2 × T ÷ Vm. The second interface echo arrives after the back wall when 2 × WP ÷ Vw is longer than 2 × T ÷ Vm, which rearranges to WP greater than T × Vw ÷ Vm.
- Focused probe: WP = F − MP × (ctm ÷ cw). Equation 13 of Evident's Ultrasonic Transducers Technical Notes (p. 8), with F the focal length in water, MP the material depth, ctm the velocity in the test material and cw the velocity in water. A focal length is quoted in water, and the faster material pulls the focal point closer, so each millimeter of steel uses up about four millimeters of focal length.
- Deepest focus: MP = F × cw ÷ ctm. The same equation with the water path at zero. A depth past this cannot be reached with that probe, and the calculator says so instead of printing a negative water path.
Worked example 1: minimum water path for 40 mm of steel
Invented numbers. Steel 1020 at 5,890 m/s, water at 1,480 m/s, a 40 mm plate.
- Vw ÷ Vm = 1,480 ÷ 5,890 = 0.2513, about one quarter.
- WP = 40 × 0.2513 = 10.05 mm.
- Check: the round trip in the part is 2 × 40 ÷ 5.89 = 13.58 µs, and the round trip in 10.05 mm of water is 2 × 10.05 ÷ 1.48 = 13.58 µs. The two match, so at exactly 10.05 mm the second interface echo sits on the back-wall echo. Use more water than that.
Worked example 2: focusing 10 mm deep in steel
Invented numbers. A probe with a 76.2 mm (3.0 in) focal length in water, focused 10 mm into the same steel plate.
- Depth in water terms = 10 × 5,890 ÷ 1,480 = 39.80 mm.
- WP = 76.2 − 39.80 = 36.40 mm.
- Deepest focus with this probe = 76.2 × 1,480 ÷ 5,890 = 19.15 mm.
- Against the 40 mm plate's minimum of 10.05 mm, a 36.40 mm water path is longer, so the second interface echo still clears the back wall.
Worked example 3: inches, and a depth the probe cannot reach
Invented numbers. A 2.0 in aluminum bar at 6,320 m/s needs at least 2.0 × 1,480 ÷ 6,320 = 0.468 in of water. Next, a probe focused at 1.5 in in water, aimed 0.5 in deep in steel: 0.5 × 5,890 ÷ 1,480 = 1.99 in, and 1.5 − 1.99 is below zero. That probe can focus no deeper than 1.5 × 1,480 ÷ 5,890 = 0.377 in in steel, so the calculator refuses the 0.5 in depth and points to a longer focal length.
These are original arithmetic examples, not exam questions. The rest of the UT General math, from wavelength to skip distance, is worked in the UT Level II formulas guide, and every velocity above comes from the ultrasonic velocity chart.
Common mistakes
- Flipping the ratio. The minimum is a fraction of the thickness for metals: water over metal, not metal over water. If the answer is four times the thickness, the velocities are upside down.
- Using the shear velocity. At normal incidence the beam in the part is longitudinal, so use the longitudinal column; see shear wave vs longitudinal wave.
- Treating the minimum as the setting. At the minimum the two echoes coincide. A real water path is set longer, by the amount your procedure calls for.
- Forgetting the focal shift. Setting the water path to the full focal length puts the focus on the front surface, not inside the part.
- Curved parts. Evident notes that a concave or convex entry surface can make the beam converge faster or spread and defocus, so Equation 13 is a flat-surface estimate.
Immersion water path questions
What is the minimum water path formula in immersion testing?
WP minimum = T × Vw ÷ Vm, where T is the part thickness, Vw the velocity in water and Vm the longitudinal velocity in the part. It is the water path whose round trip takes as long as the round trip through the part. For 40 mm of steel at 5,890 m/s with water at 1,480 m/s, WP = 40 × 1,480 ÷ 5,890 = 10.05 mm.
Why must the second interface echo come after the first back-wall echo?
Sound bounces between the probe and the part's front surface, so the interface echo repeats once every water round trip. Water is about four times slower than steel, so a short water path brings that repeat back while the part's own echoes are still arriving, where it can be read as an indication. A water path longer than T × Vw ÷ Vm pushes it past the back wall.
How do I set the water path for a focused immersion probe?
Use WP = F − MP × (ctm ÷ cw), Equation 13 of Evident's transducer technical notes, with F the focal length in water and MP the depth you want to focus at. A 76.2 mm focus aimed 10 mm deep in steel needs 76.2 − 10 × 5,890 ÷ 1,480 = 36.40 mm of water.
Why is the steel water path about a quarter of the thickness?
Because water is about a quarter as fast: 1,480 ÷ 5,890 = 0.251. Aluminum is faster than steel, so its ratio is lower, 1,480 ÷ 6,320 = 0.234. Acrylic is slower, so it needs more water per unit of thickness, 1,480 ÷ 2,730 = 0.542.
Contact and immersion technique sit under the review of ultrasonic techniques in the UT Level II General exam guide. Test yourself on why the water path matters with the ultrasonic testing quiz, or turn a transit time into a thickness with the ultrasonic thickness calculator.