Phased array UT (PAUT) vs conventional UT
Phased array ultrasonic testing (PAUT) uses a probe made of many small elements that the instrument fires with timed delays. By changing those delays, one probe steers and focuses the beam electronically and sweeps a range of angles in a sectorial scan, instead of needing a separate wedge for each angle. Conventional UT uses one element, or one transmit and receive pair, at one fixed angle set by the wedge.
Check anything you rely on against your own licensed code book and the edition your AHJ enforces.
| Conventional UT | Phased array UT | |
|---|---|---|
| Probe | One element, or a transmit and receive pair | An array of small elements, each pulsed on its own (Evident lists 16 to 256) |
| Beam angle | Fixed by the wedge | Set by the firing delays, and swept through a range |
| Focus | Unfocused, or fixed by a lens | Set electronically at a chosen depth inside the near field |
| Main display | A-scan | S-scan, linear scan and C-scan, with an A-scan for each beam |
| Coverage from one probe position | One angular path | Many angles, or many beam positions along the probe |
How the element delays steer and focus the beam
Each element sends out its own small wave. Where those waves arrive in step they add up, and where they arrive out of step they cancel. Fire the elements one after another from one end of the probe to the other and the combined wavefront tilts, so the beam leaves at an angle. A conventional wedge does the same job mechanically, because the sound crosses more plastic at one edge of the wedge than the other. The phased array does it with timing, so it can change the angle from one pulse to the next.
Fire the outer elements first and the center ones last, and the waves meet at one point. That gives a focused beam, and moving the point is just a new set of delays. One set of delays for one beam is called a focal law. The instrument's software works the focal laws out from the probe, the wedge and the material velocity, and it applies matching delays to the echoes on the way back, so every focal law gives its own A-scan.
Elements are usually fired in groups, which Evident puts at 4 to 32 elements. The group is the active aperture, and it behaves much like a conventional element of the same size. Two scan patterns come from moving either the angle or the group:
- Sectorial scan (S-scan). The same group fires at a series of angles, for example 40° to 70°, and the instrument stacks the A-scans into a fan-shaped cross-section. Only phased array equipment makes this image. On a weld, one probe position can show reflectors that a single 45° probe would only reach by moving.
- Linear (electronic) scan. The angle stays fixed, often 45°, 60° or 70° for shear waves, and the active group steps along the probe. The beam moves across the part without the probe moving, so a weld volume can be covered in one pass along its length.
Try one question
Question 1 of the free 10-question check on UT L2. No signup. About 13 minutes. Most checks include 2 calculation questions, with a calculator on the page. Then ask Echo, the AI study assistant, why the answer is right and the others are wrong.
Discontinuity Detection
A planar reflector gives its highest echo amplitude when the beam strikes it
Press A-D or 1-4 to choose an answer while this question is on screen.
Choose an answer to begin
What carries over from Level 2 UT
PAUT runs on the same physics as the UT you already study. A phased array setup asks for the same numbers a conventional one does, plus the focal law settings.
- Snell's law and the wedge. Angle beam phased array work still uses a plastic wedge to put shear waves into steel, and electronic steering moves the angle around the wedge's own angle. The critical angles guide explains why shear-wave wedges sit where they do.
- Skip distance. Every angle in an S-scan has its own half skip and full skip. The instrument works out depth and surface distance with the same trigonometry you do by hand, and draws leg lines so you can tell a first-leg reflector from a second-leg one. Check one angle yourself with the skip distance calculator.
- Near field. A beam can only be focused inside its near field, and in phased array the near field belongs to the active aperture, not the whole probe. A small group gives a short near field and a shallow limit on focus depth.
- Calibration and DAC. Each focal law is set up for wedge delay and sensitivity, so echoes from different angles can be compared and sized. Sizing still uses the DAC curve or time-corrected gain you learn for conventional UT, and some instruments build it across every focal law.
- Reading the data. A-scans, B-scans and C-scans mean the same thing on a phased array screen. The A-scan vs B-scan vs C-scan guide covers what each one plots.
Where PAUT is used
Evident names weld inspection and crack detection as the main phased array jobs, across aerospace, power generation, petrochemical plants, pipeline construction and maintenance, structural metals and general manufacturing. Corrosion mapping is the other big use: a phased array probe maps remaining wall thickness over an area and can separate mid-wall damage, such as hydrogen blistering or laminations, from wall loss.
It also earns its place on parts with awkward shapes or tight access, because the beam sweeps without the probe moving. The tradeoffs Evident lists are a higher equipment cost and the need for operator training.
How PAUT technicians are qualified
ASNT's NDT Level II program pairs a general computer-based exam with a specific exam and meets ASNT's Recommended Practice SNT-TC-1A. The employer finishes the process: ASNT states that employers carry out the visual acuity, practical and any job-specific exams their written practice calls for. ASNT's Level II exam pages list exams in MT, PT, RT, UT and VT. On 21 Nov 2026 none of them named a separate phased array exam.
For the UT exam route itself, ASNT lists 12 days of training, 120 days of UT experience and 229 days of total NDT experience, where a day is at least seven hours. What a company asks for before you run a phased array scan is set by its written practice, so ask for it. The ASNT vs employer certification guide explains how the two fit together, and the Level 2 requirements guide lists training and experience by method.
Ask Echo: Am I ready?
Ask Echo before you buy AI your AI study assistant
See what's on the UT L2 exam, test yourself with 5 quick questions, or find the plan that fits you.
The UT L2 course
Available now · instant accessLearn every General exam topic, work the calculations step by step, then prove it on timed exams.
Instant access. Terms and refunds · Secure checkout by Stripe · Billed by Nori Software
What's inside
- 7modules of lessonsEvery task on the outline
- 5full-length timed exams50 questions in 120 minutes each
- 387practice questionsEach one explained
- 5worked calculationsStep by step
- 1week-by-week study planSet to your exam date
Turn a practice answer into a study step. In untimed practice, ask Echo AI about any question you answer, follow up, then see your weakest topics and what to drill next.
- UT, MT and PT bundle$299$108 less than buying the 3 courses separatelyIncludes the UT L2, MT L2 and PT L2 courses
Terms and refunds · Secure checkout by Stripe · Billed by Nori Software
- Question of the dayFree
Every answer comes with a full explanation.
PAUT jobs and pay
No BLS wage series breaks out phased array work. BLS reports wages for the broader occupation that includes NDT specialists, not by method or technique, so a PAUT figure you see online comes from postings or surveys. Our NDT Level 2 pay guide has the BLS benchmark and posted Level II ranges, including a UT Level II posting, so you can compare like with like.
FAQ
What is the difference between PAUT and UT?
PAUT is a kind of UT. Conventional UT sends one beam at one fixed angle from a single-element probe. PAUT fires many small elements with timed delays, so one probe steers, focuses and sweeps the beam electronically and builds an S-scan image.
Do I need UT Level 2 before PAUT?
ASNT's Level II exam pages list no separate phased array exam, so there is no ASNT phased array prerequisite to point to. Your employer's written practice sets what you need before you run phased array scans. The physics PAUT uses, from Snell's law to near field and skip distance, is Level 2 UT physics.
Is PAUT on the ASNT UT Level 2 exam?
Neither of ASNT's published UT Level II topic lists, for exams before or after 5 February 2027, names phased array. The later list gives 0-degree, angle beam, pulse echo and through transmission as its examples. The exam covers conventional UT, and the UT outline change guide shows both lists side by side.
What does a PAUT course cover?
A PAUT course builds on Level 2 UT physics. Evident's free phased array tutorial is organized around the core topics: how phasing steers and focuses a beam, probes and wedges, focal law setup, linear and sectorial scans, calibrating each focal law, encoded scanning, and reading S-scans and C-scans with leg lines.
Check your UT basics free
Take the free 10-question check. It covers the UT General exam, needs no signup and explains every answer, so you see whether beam geometry, near field or another topic needs work first. The course then adds timed practice exams and a study plan built from your exam date. For the topic lists by exam date, see the UT outline change guide.
Sources
Show the list
Background reading: Evident's phased array tutorial and ASNT's NDT Level II pages, all checked 21 Nov 2026.
- Evident, phased array tutorial, table of contents. Checked 21 Nov 2026.
- Evident, introduction to phased array ultrasonic testing, element counts, groups of 4 to 32, scan formats, applications. Checked 21 Nov 2026.
- Evident, phased pulsing and its effects, electronic delays compared with a wedge's mechanical delay. Checked 21 Nov 2026.
- Evident, focusing with phased array probes, focus limited to the near field. Checked 21 Nov 2026.
- Evident, phased array imaging scans, linear and sectorial scans. Checked 21 Nov 2026.
- Evident, calibration and normalization, focal law calibration, DAC and TCG. Checked 21 Nov 2026.
- Evident, practical applications of phased array testing, weld inspection, corrosion mapping, cost and training. Checked 21 Nov 2026.
- ASNT NDT Level II certification, program, employer exams, training and experience. Checked 21 Nov 2026.
- ASNT NDT Level II examinations, methods and UT topic lists. Checked 21 Nov 2026.
Not affiliated with or endorsed by ASNT.
Angle Beam editorial team
Facts come from the sources listed above. If something has changed, tell us and we will correct it.
Your next step
Ready to see where you stand on UT L2?
Free, untimed and scored by domain. No signup. About 13 minutes. Most checks include 2 calculation questions, with a calculator on the page.
Free 10-question checkNDT UT Level II General course. Lessons, timed practice exams and a plan around your exam date.
Get NDT UT Level II General course · $149Want a timed run? Take the free 25-question practice test (about 60 minutes). No email needed.
Free tools for this topic
Prefer paper? Free printables
- Print the study checklist (free PDF). Topics to cover, on one printable page. No email.
- Print a class quiz (free PDF). 6 practice questions with an answer key on page 2.
- Print the flashcards as cut-out cards (free PDF). The free flashcard sample, ready to cut and carry.
From the blog
- UT Level II study plan: 30, 60 and 90 days
- Retaking an ASNT Level II exam: rebuild your plan
- How to study for NDT Level II while working full time