UT calibration blocks: IIW V1 and V2 explained
A UT calibration block, also called a reference standard, is a piece of metal with features at known distances. On it you set range, so the screen reads sound path correctly. You check an angle beam probe's index point and its actual refracted angle. And you set sensitivity against a known reflector. The two angle beam blocks you will meet most are the IIW type 1 block, usually called the V1, and the miniature V2.
The V1 (IIW type 1) block and what each feature sets
Sonatest lists its V1 (A2) block at 300 × 100 × 25 mm, with a 100 mm radius, a 1.5 mm hole, a 50 mm hole and engraved reference mark scales. It gives the IIW type 1 block's jobs as index point, refracted angle, resolution and sensitivity, for both angle beam (shear) and straight beam (compression) probes. Phoenix ISL sells the same V1 layout in carbon steel, stainless steel and aluminum. Evident's flaw detection tutorial notes that angle beam setup needs a block with two sound paths of known length, and it writes its setup steps around an IIW type 1 block or equivalent.
- The 100 mm radius: index point and range. Every point on an arc is the same distance from its center. The echo from the radius peaks when the beam leaves the wedge at that center, so the engraved center mark shows where the probe's index point is. The same echo is a known 100 mm sound path, which you use to set range.
- The holes: refracted angle. Peak the echo from a hole and read the engraved scale at the index point. That reading is the probe's actual angle in the block, which a worn wedge moves away from the number marked on the probe.
- The 1.5 mm hole: sensitivity. A small hole is a known reflector, so its echo can set a reference gain. Evident's tutorial notes that most procedures say how to set that reference level, often with the side-drilled hole in an IIW block or a similar reflector.
"IIW type" matters. NDE-Ed, Iowa State's NDT teaching site, explains that a true IIW block is steel only with metric dimensions, while IIW type blocks are patterned on it, come in other materials, often use inch units and may add notches and scales.
The V2 miniature block
The V2 is the small block you carry to site for small probes. Sonatest lists its V2 (A4) at 75 × 43 mm and 20 mm thick, with 12.5 and 25 mm thick versions, a 25 mm radius, a 50 mm radius and a 1.5 mm side-drilled hole. PH Tool describes the V2 as a block for on-site checks of a miniature shear wave probe's index, time base, beam angle and gain. The two radii give the two known sound paths a range setting needs, and the hole serves the angle and gain checks.
A close relative, Calibration Block No. 2 (often called K2), has the same two radii with a 5 mm hole. Sonatest lists it at 12.5 mm thick. Phoenix ISL lists its V2 and No. 2 blocks to ISO 7963 and its V1 and No. 1 blocks to ISO 2400.
Try one question
Question 1 of the free 10-question check on UT L2. No signup. About 13 minutes. Most checks include 2 calculation questions, with a calculator on the page. Then ask Echo, the AI study assistant, why the answer is right and the others are wrong.
Discontinuity Detection
A planar reflector gives its highest echo amplitude when the beam strikes it
Press A-D or 1-4 to choose an answer while this question is on screen.
Choose an answer to begin
DSC blocks and step wedges
The DSC block is an AWS-type angle beam block. PH Tool describes it as a shear wave distance and sensitivity block with a 1 in radius opposite a 3 in radius. NDE-Ed lists its uses as finding the beam exit point and refracted angle, and setting distance and sensitivity for straight and angle beam work.
Thickness gauges and straight beam setups use step wedges instead: a block with steps of known thickness. Sonatest's 5-step wedge has steps from 2.5 to 12.5 mm and is sold for thickness and linearity calibration. Evident recommends a two-point velocity and zero calibration on two samples of the test material whose thicknesses are precisely known, and two steps of a wedge give you exactly that. Check what a reading should be for a given velocity and transit time with the ultrasonic thickness calculator.
Reference blocks with side-drilled holes for DAC
A DAC curve needs the same reflector at several depths, and side-drilled holes do that job. PH Tool notes that side-drilled holes are an effective target for standardizing echo amplitude, and its ASME basic calibration blocks carry side-drilled holes for setting the primary reference response in weld examination. Sonatest's IIW type 2 block carries 1, 1.5, 2 and 3 mm side-drilled holes alongside a 50 mm and a 100 mm radius. The DAC curve guide shows how the curve is built from those holes, and the DAC curve calculator rates an echo against the points you plot.
Curved and piping blocks
A flat block suits a flat part. When the scanning surface is curved enough to change how the probe sits, the procedure specifies a curved block. PH Tool makes ASME angle beam pipe blocks and says the block should be cut from pipe that matches the part in size, schedule, heat treatment and material. For thickness work on tube, Sonatest sells a 5-step wedge curved to fit outside surfaces. The written procedure, and the code it follows, such as ASME Section V Article 4, decides which block a pipe job needs.
Why the block's material and velocity must match the part
A block only sets range and angle correctly if sound travels through it at the same speed as through the part. Evident's tutorial says calibration should be done on a block made of the same material as the test piece, and that angle beam blocks are sold in several steel alloys as well as aluminum and titanium. NDE-Ed and PH Tool say the same: make the reference standard from the material being inspected, or as close to it as possible.
Here is what a mismatch costs. Set range on a steel block, where the shear velocity is about 3,240 m/s, then scan an aluminum part, where it is about 3,130 m/s. A reflector at a true 100 mm sound path takes 2 × 100 ÷ 3.13 = 63.9 µs for the round trip, and the screen, still set for steel, shows 3.24 × 63.9 ÷ 2 = 103.5 mm. The refracted angle changes too, because the wedge was cut for steel. The ultrasonic velocity guide has the velocities for twelve common materials.
Ask Echo: Am I ready?
Ask Echo before you buy AI your AI study assistant
See what's on the UT L2 exam, test yourself with 5 quick questions, or find the plan that fits you.
The UT L2 course
Available now · instant accessLearn every General exam topic, work the calculations step by step, then prove it on timed exams.
Instant access. Terms and refunds · Secure checkout by Stripe · Billed by Nori Software
What's inside
- 7modules of lessonsEvery task on the outline
- 5full-length timed exams50 questions in 120 minutes each
- 387practice questionsEach one explained
- 5worked calculationsStep by step
- 1week-by-week study planSet to your exam date
Turn a practice answer into a study step. In untimed practice, ask Echo AI about any question you answer, follow up, then see your weakest topics and what to drill next.
- UT, MT and PT bundle$299$108 less than buying the 3 courses separatelyIncludes the UT L2, MT L2 and PT L2 courses
Terms and refunds · Secure checkout by Stripe · Billed by Nori Software
- Question of the dayFree
Every answer comes with a full explanation.
Standards and buying a block
Block designs follow published standards: ISO 2400 for the No. 1 and V1 blocks, ISO 7963 for the No. 2 and V2 blocks, and ASME Section V Article 4 for the basic and pipe blocks used in weld examination. Prices vary by maker, material and certification, and Sonatest and Phoenix ISL both quote on request.
Calibration on the UT Level II General exam
For exams taken up to 5 February 2027, calibration and reference standards sit under the General evaluation topic in ASNT's UT General outline, and the UT Level 2 General exam guide lists every topic. Expect to say which block feature checks the index point or the angle, why a block must match the part, and how a DAC is built from side-drilled holes. The angle beam testing guide shows where the probe check fits in a weld scan.
Know your blocks? Check the rest of the UT General topics
Take the free 10-question check. It covers the UT General exam, needs no signup and explains every answer, so you see which topic to study next. The course then adds timed practice exams and a study plan built from your exam date.
FAQ
What is a V1 calibration block used for?
The V1, or IIW type 1 block, sets range on the 100 mm radius, locates an angle beam probe's index point and checks its refracted angle against the engraved scales. Its 1.5 mm hole gives a known reflector for setting sensitivity, and it serves straight beam probes too.
What is the difference between a V1 and a V2 block?
The V1 is a full-size 300 × 100 × 25 mm block with a 100 mm radius. The V2 is a miniature block, about 75 × 43 mm, with a 25 mm and a 50 mm radius, built for checking small angle beam probes on site.
Which calibration block does my procedure require?
The written procedure governs. It names the block, its material and any curvature, and the code it follows sets the rest. When the part's material or curvature differs from the block, the procedure says what to use instead.
Where do our practice questions come from?
Every question is original and written to ASNT's published outline for the Level II General exam.
Sources
Show the list
- Sonatest, V1 / A2 Block: V1 dimensions, radius, holes and scales. Checked 21 Nov 2026.
- Sonatest, V2 / A4 Block: V2 dimensions, thicknesses, radii and hole. Checked 21 Nov 2026.
- Sonatest, IIW Type 1 Block and IIW Type 2 Block: uses and features. Checked 21 Nov 2026.
- Sonatest, No2 / K2 Block, 5 Step Wedge and 5 Step OD Curved Wedge. Checked 21 Nov 2026.
- Phoenix ISL, Calibration Block V1 (A2): materials and the ISO 2400 and ISO 7963 block families. Checked 21 Nov 2026.
- PH Tool, V2 (A4) Test Block, DSC Block, ASME Sec V Basic Calibration Block and ASME Sec V Pipe Calibration Blocks. Checked 21 Nov 2026.
- PH Tool, Reference Standards for NDT: side-drilled holes and matching the material. Checked 21 Nov 2026.
- NDE-Ed (Iowa State University), Calibration Methods: IIW type blocks, DSC block, step wedges and reference standard material. Checked 21 Nov 2026.
- Evident, Ultrasonic Flaw Detection Tutorial: section 3.6 (calibration concepts and two-point calibration), section 4.3 (angle beam setup and block material) and section 6.6 (reference gain from a side-drilled hole). Checked 21 Nov 2026.
- Shear velocities for steel and aluminum from our ultrasonic velocity guide, which cites Evident's Technical Notes Table 2.
Not affiliated with or endorsed by ASNT.
Angle Beam editorial team
Facts come from the sources listed above. If something has changed, tell us and we will correct it.
Your next step
Ready to see where you stand on UT L2?
Free, untimed and scored by domain. No signup. About 13 minutes. Most checks include 2 calculation questions, with a calculator on the page.
Free 10-question checkNDT UT Level II General course. Lessons, timed practice exams and a plan around your exam date.
Get NDT UT Level II General course · $149Want a timed run? Take the free 25-question practice test (about 60 minutes). No email needed.
Free tools for this topic
Prefer paper? Free printables
- Print the study checklist (free PDF). Topics to cover, on one printable page. No email.
- Print a class quiz (free PDF). 6 practice questions with an answer key on page 2.
- Print the flashcards as cut-out cards (free PDF). The free flashcard sample, ready to cut and carry.
From the blog
- What Is Ultrasonic Testing? Method, Steps and Results
- UT Level II practice questions with worked answers
- The math behind NDT Level II: algebra, trig and units